M 150/6"

Discription:

  • Material: UV resistant plastic (prevents ageing caused by exposure to sunlight).
  • Nominal diameter 150 mm.
  • Motor protected against thermal overload, with shaft turning in self-lubricating bushings, coupled to screw type thermoplastic impeller with wing profile blades.
  • Maximum air flow: 335 m3/h.
  • IMQ SAFETY and IMQ PERFORMANCE certifications.
  • Vortice speed controller.
  • Absorbed Current max (A)
    0,15
  • Absorbed Power max (W)
    30
  • Frequency (Hz)
    50
  • Insulation Class
    II°
  • IP
    X4
  • Max ambient temperature for continuous operation (°C)
    50
  • Nominal Diameter (mm)
    156
  • Ø Discharge Hole (mm)
    156
  • Voltage (V)
    220-240
  • Weight (Kg)
    1,1
  • Delivery max (l/s)
    93,1
  • Delivery max (m³/h)
    335
  • Pressure max (mmH2O)
    6
  • Pressure max (Pa)
    59
  • RPM
    2100
  • Sound Pressure level Lp [dB (A)] 3m
    46
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption class SEC in average climate zone
    NA
  • Specific Energy Consumption class SEC average [kWh/m2a]
    -9,7
  • Specific Energy Consumption class SEC cold [kWh/m2a]
    -23,0
  • Specific Energy Consumption class SEC warm [kWh/m2a]
    -2,0
  • Declared typology
    UVR-U: unidirezionale
  • Type of drive
    NA
  • Type of heat recovery system HRS
    assente
  • Thermal efficiency of heat recovery at reference air flow [%]
    NA
  • Maximum flow rate [m3/h]
    324
  • Electric power input of the fan drive, including any motor control equipment, at maximum flow rate [W]
    27,8
  • Sound power level LWA [dB(A)]
    67
  • Reference flow rate [m3/s]
    0,0630
  • Reference pressure difference [Pa]
    28
  • SPI [W/(m3/h)]
    0,12434
  • Control factor CTRL
    1
  • Control typology
    manuale
  • Maximum internal leakage rates [%]
    NA
  • Maximum external leakage rates [%]
    NA
  • Mixing rate
    NA
  • Position and description of visual filter warning
    NA
  • Airflow sensitivity to pressure variations at + 20Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/a]
    171
  • AHS average Annual heating saved [kWh primary energy/a]
    1397
  • AHS cold Annual heating saved [kWh primary energy/a]
    2732
  • AHS warm Annual heating saved [kWh primary energy/a]
    632
  • Etichetta Energetica
    NO
  • Size A (mm)
    Ø 155
  • Size B (mm)
    110
  • Size C (mm)
    107
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption class SEC in average climate zone
    NA
  • Specific Energy Consumption class SEC average [kWh/m2a]
    -4,1
  • Specific Energy Consumption class SEC cold [kWh/m2a]
    -17,5
  • Specific Energy Consumption class SEC warm [kWh/m2a]
    3,5
  • Declared typology
    UVR-U: unidirezionale
  • Type of drive
    NA
  • Type of heat recovery system HRS
    assente
  • Thermal efficiency of heat recovery at reference air flow [%]
    NA
  • Maximum flow rate [m3/h]
    68
  • Electric power input of the fan drive, including any motor control equipment, at maximum flow rate [W]
    14,0
  • Sound power level LWA [dB(A)]
    54
  • Reference flow rate [m3/s]
    0,0132
  • Reference pressure difference [Pa]
    14
  • SPI [W/(m3/h)]
    0,28571
  • Control factor CTRL
    1
  • Control typology
    manuale
  • Maximum internal leakage rates [%]
    NA
  • Maximum external leakage rates [%]
    NA
  • Mixing rate
    NA
  • Position and description of visual filter warning
    NA
  • Airflow sensitivity to pressure variations at + 20Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/a]
    394
  • AHS average Annual heating saved [kWh primary energy/a]
    1397
  • AHS cold Annual heating saved [kWh primary energy/a]
    2732
  • AHS warm Annual heating saved [kWh primary energy/a]
    632
  • Etichetta Energetica
    NO
  • Size A (mm)
    214
  • Size B (mm)
    215
  • Size C (mm)
    117
  • Size D (mm)
    47
  • Size E (mm)
    Ø 156

Accessories

Discover accessories related to the product

SCNRB SCAT.COM.NON REV.INCASSO

• Non-reversible electronic speed controller. • Built-in.

F 150/6"

• Window mounting kit.

S 150/6

• Ceiling kit made of soft rubber to prevent water infiltration and to maintain IPX4 protection on all surfaces.

KIT SCB (TRASF.E.C.)

• Built-in controller adaptor.